What should be paid attention to when using stainless steel lock weights?

2023-06-05
For stainless steel weights, their shape is usually a lock shape. Is there anything worth noting in daily use? Let's follow the staff of the stainless steel lock weight to take a look!

Stainless steel lock weight
Stainless steel lock weight
It should be reminded that when using stainless steel weights, it is important to pay attention to operating standards. Firstly, check the stainless steel weight you want to use to see if there are any stains on the surface. If there is any dirt or dust, it needs to be cleaned before use. Check if the weights are within the calibration period. Weights that exceed the calibration period need to be calibrated before use.

Although the stainless steel lock weight is made into a handle shape, you cannot use it directly, but wear gloves to hold it. Before use, clean the surface of the stainless steel lock weight with a cleaning brush and silk cloth to ensure that the heavy surface is free of stains and dust. During use, the preferred environment for using weights is constant temperature.

The surface roughness, accuracy and magnetic susceptibility of stainless steel weights will be discussed today. From this, it can be seen that the error of the standard weight grade can be verified by the metrological institution. Weight verification requires a stable environmental foundation. Therefore, we need to place the weights in the measuring instrument before inspection to reduce the temperature difference between the weights and the measuring instrument. In addition to verifying the stability of the environment, the temperature in the laboratory also needs to be stable! During the calibration process, the higher the weight level, the higher the requirement for temperature change, and different levels have different specifications and temperature change ranges. So, for weights of class F and above, we not only need to pay attention to temperature stability, but also to humidity. The humidity in the laboratory needs a standard range and cannot exceed this range.

If there is any doubt about the quality during the use of stainless steel weights, they need to be sent to the metrology department for inspection and calibration. If there are slight errors in the quality, the standard weight can be adjusted by adjusting the cavity. If the stainless steel weights are severely worn, it is recommended to purchase them again. In this case, the weights cannot make up for the weight.

contact us

National Service Hotline

159-5359-3777

Website:http://e8d8ua9.2.magic2008.cn/

Email:sales@hmweight.com

Address:North of Fumin Road, Penglai City, Shandong Province Phone: